  3.  8739 BF    946   0 07-Dec 0504 KD2EJ  28376_WB2QJA INFO@ALLBBS ()
  4.  Sb: R-5000 IMPROVE VOLTAGE SURGE
  5.  
  6.  
  7.  
  8. SB-919
  9.  
  10. R-5000 No Freq. Change thru Computer Interface                 7-21-87
  11.  
  12.  
  13. R-5000 receivers below serial number 804xxxx may not change frequency when
  14. operated with a personal computer/interface.  To allow correct operation,
  15. rplace IC-52 on the Control Unit.  The correct part number for IC-52 is
  16. MBM27C128-25JA2.
  17.  
  18. CAUTION:
  19.  
  20. The R-5000 incorporates CMOS technology.  Observe precautions for handling
  21. electrostatic sensitive devices.
  22.  
  23. This modification may be performed under warranty.